| Measuring range |
0 ... 5000μm |
| Resolution | 0 ... 99.9μm: 0.1μm 100 ... 999μm: 1.0μm 1.0 ... 5.0mm: 0.01mm |
| Probe | Dual probe, automatic substrate selection Fe/NFe 1 |
| Measuring method | Magnetic (Magnetic flux/Hall effect) or eddy current 2 |
| Standards |
DIN EN ISO 2808, ISO 2178, ISO 2360, ASTM B 499, ASTM D 7091
|
| Measuring modes | Individual measurement, Measurement with structured storage |
| Measuring interval | ca. 1500ms |
|
Measuring accuracy 2) |
0 ... 2000μm: ± (1 μm +2% of the measurement)
|
| Memory capacity | max. 10 jobs max. 200 parts max. 10000 measurements |
| Settings | Radio on/off, display system info, buzzer on/off, date/time, unit μm/mil, display light on/off, display orientation normal/flipped |
|
Measuring surface |
min. 20 × 20 mm |
|
Radius of curvature |
convex min. 5mm concave min. 30mm |
|
Smallest substrate thickness |
Fe: 0.2mm NFe: 0.05mm |
| Interface | Wireless 2.4GHz, range max. 10m (in free field) |
| Temperature range | Operation: 0 ... 50°C, storage: –10 ... 60°C |
| Power supply | 2 AA size batteries 1.5V AlMn, or 2 AA size rechargeable batteries 1.2V |
| Power supply | 2 AA size batteries 1.5V AlMn, or 2 AA size rechargeable batteries 1.2V |
|
Dimensions |
(length × width × height) 68 × 33 × 125 mm |
| Weight | 125g incl. batteries |
| 1) | Measurements of non-ferromagnetic coating on ferromagnetic substrate (such as lacquer on steel or iron) and measurements of non-ferromagnetic and non-conductive coatings on non-ferromagnetic and conductive substrate (such as lacquer on aluminum, zinc, copper or brass) |
| 2) | Manufacturer’s calibration in regard to the supplied zero reference plates |
Subject to technical modifications